Buffer CB or Buffer IR may precipitate and precipitate at low temperatures. It can be dissolved again in a water bath at 37℃ for a few minutes to restore clarity and transparency. After cooling to room temperature, it can be used.
Proteinase K is stored in a ready to use glycerol buffer and transported at room temperature. After receipt, store at room temperature not exceeding 25℃ for at least 6 months, at 4℃ for 12 months, and at -20℃ for 2 years.
To avoid volatilization, oxidation, and pH changes caused by prolonged exposure of reagents to the air, each solution should be covered tightly in a timely manner after use.
Components
Component
Storage
DNK3201 50 times
DNK3202 100 times
DNK3203 200 times
Balance Buffer
RT
5 ml
10 ml
20 ml
Buffer FTL
RT
11 ml
20 ml
40 ml
Buffer CB
RT
11 ml
20 ml
40 ml
Buffer IR
RT
25 ml
50 ml
100 ml
Buffer WB
RT
13 ml
25 ml
50 ml
Buffer EB
RT
15 ml
15 ml
15ml×2
Proteinase K
-20℃
1.5ml
3ml
6ml
Adsorption column AC
RT
50
100
200
Collection tube (2ml)
RT
50
100
200
Description
Formalin fixed or paraffin embedded tissues are rapidly lysed by unique Buffer FTL heat treatment and Proteinase K to release genomic DNA. The genomic DNA is then selectively adsorbed onto the silica matrix membrane in a high dissociation salt state in a centrifuge column, followed by a series of rapid rinsing centrifugation steps. Buffer IR and Buffer WB remove impurities such as cell metabolites and proteins, Finally, low salt Buffer EB elutes pure genomic DNA from the silica matrix membrane.
Features
The silicon matrix membrane inside the centrifugal adsorption column is entirely made of specially designed adsorption membranes from world-renowned imported companies, with minimal differences in adsorption capacity between columns and good repeatability. Overcoming the drawback of unstable membrane quality in domestic reagent kits.
No toxic reagents such as phenol are required, and no steps such as ethanol precipitation are required.
Fast and simple, the operation of a single sample can generally be completed within 30 minutes.
Multiple column washes ensure high purity, with a typical OD260/OD280 ratio of 1.7~1.9 and a length of up to 30kb-50kb. It can be directly used for PCR, Southern blot, and various enzyme digestion reactions.
Application
Suitable for rapid extraction of DNA from various formalin fixed and paraffin embedded tissues